Computed aided detection of traumatized kidneys in CT images
(Institute of Electrical and Electronics Engineers Inc., 2017)
In this work, we developed a novel method to diagnose traumatized kidney in the presence of laceration, contusion and active bleeding due to abdominal trauma. Our CAD system performs 94,44% of sensitivity at 0.13 false ...
Automatic Detection of Pulmonary Embolism in CTA Images Using Machine Learning
(Kaunas Univ. Technology, 2017)
In this study, a novel computer-aided detection (CAD) method is introduced to detect pulmonary embolism (PE) in computed tomography angiography (CTA) images. This method consists of lung vessel segmentation, PE candidate ...
A CAD of fully automated colonic polyp detection for contrasted and non-contrasted CT scans
(Springer, 2017)
Computer-aided detection (CAD) systems are developed to help radiologists detect colonic polyps over CT scans. It is possible to reduce the detection time and increase the detection accuracy rates by using CAD systems. In ...
Variable antenna-space shift keying for high spectral efficiency in exponentially correlated channels
(Wiley, 2017)
the case of correlated channels. Then, to reduce the correlation effect, a novel antenna codeword construction method that minimizes the pairwise error probability is introduced for exponentially correlated channels. ...
Classification of Neuromuscular Junction and Tendon Recordings of Neuromuscular Diseases by Their Spectrogram
(IEEE, 2017)
In this study, the effect of spectrograms from neuromuscular junction and tendon records for normal, neurogenic and myopathic motor units being constructed via EMG Simulator v3.6 on the differential diagnosis were investigated. ...
Observation of the Effect of the Increase in Luminance Level on Emotional Assessment in EEG Records Using Welch Method
(IEEE, 2017)
The aim of this study is to investigate the effect of the difference in level of luminance of visual stimuli on the emotional evaluation (negative, positive, neutral) from electroencephalogram (EEG) data recorded. EEG ...
Butterworth Based Kidney Volume Calculation
(IEEE, 2017)
The width, thickness and the length of the organs are frequently used for volume calculations in radiology. Thus, radiologists can determine the approximate volumes of the regions rapidly. In this work Butterworth based ...
Detection of Injured Kidney in Computed Tomography
(IEEE, 2017)
Timely and accurate diagnosis of intraabdominal organ injuries due to trauma is critical. Computer Assisted Detection (CAD) systems are rapidly developing techniques to segment the organs or to detect the pathologies in ...
Investigation of Luminance Effect on the Emotional Assessment Using Principle Components Analysis Method
(IEEE, 2017)
The purpose of the study is to observe the effect of the level of luminance on the emotional evaluation (positive, negative, neutral) in electroencephalography (EEG) records. EEG records of 31 healthy volunteers were used ...
Classification of Neuromuscular Diseases in Neuromuscular Junction and Tendon Recordings with Needle EMG by Using Welch's Method
(IEEE, 2017)
In this study, the power spectral density of simulated data which contain neuromuscular diseases and normal motor unit (i.e. control group) scenarios was calculated using Welch's method. Furthermore, the effect of Welch's ...