Ara
Toplam kayıt 40, listelenen: 31-40
Design, Implementation and Performance Analysis of a Microcontroller based Wireless Electromyography Device
(IEEE, 2017)
Elektromyography (EMG) signals are the electrical signals that are emerged by muscular contraction. In this study, a wireless EMG device was designed and implemented. The EMG signals are collected by surface electrodes, ...
Classification of Neuromuscular Diseases in Neuromuscular Junction and Tendon Recordings with Needle EMG by Using Welch's Method
(IEEE, 2017)
In this study, the power spectral density of simulated data which contain neuromuscular diseases and normal motor unit (i.e. control group) scenarios was calculated using Welch's method. Furthermore, the effect of Welch's ...
Dynamic time warping based connectivity classification of event-related potentials
(Institute of Electrical and Electronics Engineers Inc., 2019)
Human brain electrical responses measured as Electroencephalogram epochs have different characteristics by means of amplitude and frequency content depending on the conditions and stimuli. Event-related potentials are the ...
Development of a new algorithm for the estimation of the step percentage in compound muscle action potential scan
(Institute of Electrical and Electronics Engineers Inc., 2019)
Compound Muscle Action Potential (CMAP) Scan used in the diagnosis and in the monitoring of Neuromuscular Diseases is based on recording the responses obtained from the gradual stimulation of a peripheral nerve. Clearly ...
Determining Phase Duration of Scanning EMG Signals
(IEEE, 2015)
There are more than one motor unit activities recorded simultaneously during scanning EMG recordings. It is not possible to determine the phase duration correctly by inspecting only one sweep. The other motor unit activities, ...
Investigation of the Effect of Fiber Diameter Variability via Recording from Tendon via of Single Fiber Electromyography
(IEEE, 2015)
In this preliminary study, two muscle fibers which one of them had a constant fiber diameter and the other had a variable fiber diameter were created by using an EMG simulator. Single Muscle Fiber Action Potentials (SMFAPs) ...
Self-organizing maps for brain tractography in MRI
(IEEE, 2013)
Brain white matter fibers can be mapped synthesizing the diffusion tensors obtained from diffusion weighted magnetic resonance images. An important drawback in the determination of the fiber paths for tractography purposes ...
Synthesis and characterization of molecularly imprinted polymer from renewable sources
(Institute of Electrical and Electronics Engineers Inc., 2021)
In this study, molecular imprinted polymers targeting the potent antibiotic ciprofloxacin were prepared for the first time using renewable resources. Lactic acid maleic acid ester, methylene bisacrylamide, potassium ...
Studying the Liason between Motor Unit Number Estimate (MUNE) and the Total Slope of a Stimulus-Response (SR) Curve of Compound Muscle Action Potential (CMAP) Scan
(Institute of Electrical and Electronics Engineers Inc., 2021)
Objective: This study aims to reveal the connection between the MUNE and the Total Slope of the SR Curve of the CMAP Scan. Introduction: MUNE being a neurophysiological method is utilized in diagnosing and monitoring ...
Comparison of machine learning techniques on MS lesion segmentation
(Institute of Electrical and Electronics Engineers Inc., 2019)
Multiple sclerosis arises with conformational change in myelin sheath. Magnetic resonance imaging is frequently used in detection of MS. In this study, to figure out MS lesion, machine learning techniques, namely k means ...