Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorZhou, Yuweien_US
dc.contributor.authorTeomete, Uygaren_US
dc.contributor.authorDandin, Özgüren_US
dc.contributor.authorOsman, Onuren_US
dc.contributor.authorDandinoğlu, Taneren_US
dc.contributor.authorBağcı, Ulaşen_US
dc.contributor.authorZhao, Weizhaoen_US
dc.date.accessioned2017-04-21T13:02:17Z
dc.date.available2017-04-21T13:02:17Z
dc.date.issued2016
dc.identifier.citationZhou, Y., Teomete, U., Dandin, Ö., Osman, O., Dandinoğlu, T., Bağcı, U., Zhao, W. (2016). Computer-aided detection (CADx) for plastic deformation fractures in pediatric forearm. Computers in Biology and Medicine. 78, 120-125.en_US
dc.identifier.issn0010-4825
dc.identifier.urihttps://hdl.handle.net/20.500.12294/816
dc.descriptionOsman, Onur (Arel Author)en_US
dc.description.abstractBowing fractures are incomplete fractures of tubular long bones, often observed in pediatric patients, where plain radiographic film is the non-invasive imaging modality of choice in routine radiological workflow. Due to weak association between bent bone and distinct cortex disruption, bowing fractures may not be diagnosed properly while reading plain radiography. Missed fractures and dislocations are common in accidents and emergency practice, particularly in children. These missed injuries can result in more complicated treatment or even long-term disability. The most common reason for missed fractures is that junior radiologists or physicians lack expertise in pediatric skeletal injury diagnosis. Not only is additional radiation exposure inevitable in the case of misdiagnosis, but other consequences include the patient's prolonged uncomfortableness and possible unnecessary surgical procedures. Therefore, a computerized image analysis system, which would be secondary to the radiologists’ interpretations, may reduce adverse effects and improve the diagnostic rates of bowing fracture (detection and quantification). This system would be highly desirable and particularly useful in emergency rooms. To address this need, we investigated and developed a new Computer Aided Detection (CADx) system for pediatric bowing fractures. The proposed system has been tested on 226 cases of pediatric forearms with bowing fractures with respect to normal controls. Receiver operation characteristic (ROC) curves show that the sensitivity and selectivity of the developed CADx system are satisfactory and promising. A clinically feasible graphical user interface (GUI) was developed to serve the practical needs in the emergency room as a diagnostic reference. The developed CADx system also has strong potential to train radiology residents for diagnosing pediatric forearm bowing fractures.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.ispartofComputers in Biology and Medicineen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBowing Fractureen_US
dc.subjectPlastic Deformationen_US
dc.subjectRadiusen_US
dc.subjectUlnaen_US
dc.subjectCADxen_US
dc.titleComputer-aided detection (CADx) for plastic deformation fractures in pediatric forearmen_US
dc.typearticleen_US
dc.departmentİstanbul Arel Üniversitesi, Mühendislik ve Mimarlık Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü.en_US
dc.authoridTR13219en_US
dc.identifier.volume78en_US
dc.identifier.startpage120en_US
dc.identifier.endpage125en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US